Cancelled [UE05J45] KDR AU and Momentum KXR – Oct 24 – Oct 27 (Private Event) – CANCELLED
Event Phone: 919-792-6420
-
Day 1 - Day 3
October 24, 2023 - October 26, 2023
9:00 am - 4:00 pm -
Day 4
October 27, 2023
9:00 am - 11:00 am
Course Objective:
This is a private event by invite only for our LATAM dealer service engineers.
This seminar will provide each attendee with the skills to effectively service and install the following components of Konica Minolta DR systems:
-KDR® AU and Primary System
-Sedecal Generators
-AeroDR Detectors
-Momentum KXR Floor Mount System
-Ultra Software
Note: Last day end time: 11:00AM. See details in Course Specifications below.
Additional Information:
COVID-19 Protocols
- Those exposed to the virus are no longer required to quarantine. However, it is recommended to wear a high-quality mask for 10 days and get tested again on day 5.
- If you test positive for COVID-19, you should stay home for at least 5 days.
- Unvaccinated people now have the same guidance as vaccinated people.
- Students attending training are no longer required to provide proof of vaccination.
Prerequisites
- Minimum two (2) years X-ray service experience
- Windows operating system experience
- Ability to read and comprehend schematics drawings
- Minimum two (2) years electronics trouble-shooting experience
Target Audience
Service Engineers
Course Specifications
Course Length: 4 days
Hours: Tue – Thurs: 9:00AM to 4:00PM
Friday: 9:00AM – 11:00AM
Lunch will be at 12:00
Course Topics
Topics may vary depending upon prior class knowledge and experience
Day 1:
Overview
- Mission statement
- Advantages of Digital Radiography
- Course expectations
- Safety overview
- Introduction to manuals
Overview of the KDR™ AU/Primary
- Design and similarities
- Site planning guides
- Minimum room requirements
- Mandatory site preparation
- Sub-assemblies
- Theory of operation
- Interfaces to other elements
- Introduction to the major system components
- Review diagram of interconnect cables
Day 2: Sedecal Generator
- Installation process
- Configuration of tube and stator
- Workstation setup
- Calibration
- AEC
- Circuit analysis
- Troubleshooting
Day 3: Overview of the DR Panels
- Review the multiple components
- Basic operation of a Flat Panel
- Optimal performance specifications
- Sub-assembly
- Theory of operation
Lab
- Identify replaceable components
- Connect & wire Imaging Detector
- Configure & calibrate the stand
- Configure & calibrate the generator
Ultra Software
- Application of Tech Service
- Log-in requirements
- Operation of the Ultra application
- Image acquisition
- Scheduling & performing studies
- Navigating images
- Send & print image functions
- DICOM Configuration
- Service level philosophy
Day 4: Momentum KXR
- Installation
- Service
- Maintenance
Venue: Konica Minolta Healthcare Americas, Inc.