Course Objective:
This seminar will provide each attendee with the skills to effectively service and install the following components of Konica Minolta DR systems:
-KDR® AU and Primary System
-Sedecal Generators
-AeroDR Detectors
-Sedecal Straight Arm
-Ultra Software
Note: Last day end time: 12:00PM. See details in Course Specifications below.
Additional Information:
Prerequisites
- Minimum two (2) years X-ray service experience
- Windows operating system experience
- Ability to read and comprehend schematics drawings
- Minimum two (2) years electronics trouble-shooting experience
Target Audience
Service Engineers
Course Specifications
Course Length: 4 days
Hours: Tue – Thurs: 8:30AM to 5:00PM
Friday: 8:30AM – 12:00PM
Lunch will be at 12:00
Course Topics
Topics may vary depending upon prior class knowledge and experience
Day 1:
Overview
- Mission statement
- Advantages of Digital Radiography
- Course expectations
- Safety overview
- Introduction to manuals
Overview of the KDR™ AU/Primary
- Design and similarities
- Site planning guides
- Minimum room requirements
- Mandatory site preparation
- Sub-assemblies
- Theory of operation
- Interfaces to other elements
- Introduction to the major system components
- Review diagram of interconnect cables
Day 2: Sedecal Generator
- Installation process
- Configuration of tube and stator
- Workstation setup
- Calibration
- AEC
- Circuit analysis
- Troubleshooting
Day 3: Overview of the DR Panels
- Review the multiple components
- Basic operation of a Flat Panel
- Optimal performance specifications
- Sub-assembly
- Theory of operation
Lab
- Identify replaceable components
- Connect & wire Imaging Detector
- Configure & calibrate the stand
- Configure & calibrate the generator
Ultra Software
- Application of Tech Service
- Log-in requirements
- Operation of the Ultra application
- Image acquisition
- Scheduling & performing studies
- Navigating images
- Send & print image functions
- DICOM Configuration
- Service level philosophy
Day 4 (half day):
- Straight Arm Installation process
- Site planning
- Calibration
- Review of generator, positioners and panels
- Troubleshooting
- Feedback
Venue: Konica Minolta Healthcare Americas, Inc.
Address: